Wall Split Type Ultrasonic Level Meter
Author:admin date:2010-06-01 17:00:21 views:5165
【close】
Technical parameters
Working voltage: 220V
DC12V, DC24V
Detection methods: continuous detection 0.1hz ~ 100hz / s (default 1hz / s)
Detection range: 1,2,3,5, ... ... 50 meters (custom)
Working frequency: 20khz ~ 75khz (due to scale and model specifications are different)
Display resolution: d = 1mm/1cm ... ... calibration set or when the selection order
Display: LCD display LCD + backlight
Blind: ≤ 200mm ~ 1000mm (for range and different)
Accuracy: 0.2 ~ 0.5% F · S
Data output: 4 ~ 20mA (default); 0 ~ 20mA (custom)
0 ~ 5V, 1 ~ 5V voltage output
1 to 4 groups switch signal output
1 to 4 relay outputs
RS485/232 serial data output
(Based on user requirements can also customize a variety of different output modes)
Keyboard: The three touch keys
Operating temperature: 0 ~ 50 ℃ (default); -20 ~ 70 ℃ (custom)
Working humidity: ≤ 80% RH, no condensation
Storage temperature: -40 ~ 85 ℃
Storage humidity: ≤ 70% RH, no condensation
Sensor lead: 10 meters (standard)