中文
Oline:QQ 1071557730
Fax:+86-023-68698258
Add:7th Floor, 166# Keyuan 3rd Rd, Hi-tech district, Chongqing, China
Email:zykjrisen@126.com
Hotline:+86-023-68698158
                 +86-023-68698258
                 +86-023-68796059

  Products

 
 

 Products

Site:Homepage -> Product -> RISEN-Ultrasonic flow meter series -> Ultrsonic open flow meter -> Detail
Name:Split type ultrasonic open channel flow meter
Type:RISEN-WS
Views:7078

The main technical indexes: 

Product model

RISEN-WS

Applicable weir

Right triangle weir slot (opening size: 500 mm)

Bashir slot (larynx way width: 51 mm, 76 mm, 152 mm, 228 mm, 300 mm)

Rectangular weir (opening size: 250 mm, 500 mm, 750 mm)

When conditions need to choose according to order a barrage the slot, a specification

Flow range

According to different specifications applicable weir slot

Flow precision

5% F·S

Level range

1m

Level precision

0.5% F.S (at times, and the blind process ℃)

Probe blind area

300mm (at 25 ℃)

Output signa

4 ~ 20 mA three wire system

Showing the way

LED display,Among them:Four level height

Four transient flow

Eight of the accumulative total flow

16 the calendar clock (buttons when)

Working temperature

0 ~ + 50 ℃

Work power

AC220V / 50Hz

Outlet way

Sensor leads 20 m, instrument standard plugs

Installation

instrument wall hung installation; Sensor gongs grain installation M49 x 1.5, or gongs circle clampon installation

Protection level

Sensor IP65

Product display:


   
Wiring definition:

 

The main function characteristics: 

· With a fully independent intellectual property rights

· Has wide range of temperature compensation and original ERD interference intelligent identification system, measurement data stability, high precision.

· Six groups flow condition all data sending 485 serial ports output, PC directly receive, decimal shows, the convenient user record and read archived.

· Original "fluid flow correction system" that flow coefficient according to slot size and level to be automatic operation weir and timing compensation.

· The blackout time time, the year/month/day/when/points/SEC, flow data, using the ferroelectric double backup storage 10 years off.

· Original "measuring tank jam recognition alarm system" can detect liquid slag quality measurement slot throat and obstruction caused by measurement.

· Precise date determined when the calendar clock Settings, display and cooperate with the memo and time axis to file information records.

· Has 4 ~ 20 mA three wire system, RS485, switch quantity and so on many kinds of signal output function selection.

· Using intelligent measuring high, digital calibration, the user installation calibration simple and quick

· The ultrasonic non-contact measurement with no moving parts, flow without components within, no block sensor fault hidden trouble.